Contents
1. The Operation of Machine
2. Troubleshooting……………………………………………….....................
3.Cleaning and Maintenance
(1) Installing Places ………………………………………………………..
(2) Cleaning………………………………………………………………….
(3) Maintenance……………………………………………………….........
Before Operation
chute.
① The peripheral orbiter and the inner orbiter should be parallel to each other with
a width slightly larger than the diameter of the tablet or capsule to be counted,
and the discharge opening should be placed in the middle of the electric eye
socket.
② The front end of the peripheral orbiter should be attached to the circumference,
and the capsule will be smooth when it slides.
③ Adjust the deflector so that its height is slightly larger than the thickness of the
tablet.
of the granule.
Adjust the height of the lifting plate and lock the positioner.
Turn on the power, set the number, and start the turntable and vibrator slowly.
Then check whether the slide is smooth, and the screen display is correct. If it is
normal, you can start the operation.
During 0peration
If the tablet loses a lot of powder during work, it can be connected to the vacuum cleaner to suck out the dust.
The following tables are reference values:
tablet diameter:6mmφ | φ speed scale is about: | 30~40 |
tablet diameter:8mmφ | φ speed scale is about: | 35~50 |
tablet diameter:10-12mm | φ speed scale is about: | 40~55 |
capsule: #4-#00 | φ speed scale is about: | 45~55 |
General operation, speed can reach: | 1000-2000 pieces per minute |
During operation, the vibration discharge should match the speed of the turntable, and the disk surface should not be accumulated to avoid the track blockage. Pay special attention to the capsules. If there are too many blanks, it will easily overlap or block in the orbiter, which will result in inaccurate counting.
2. Troubleshooting
Please contact the manufacturer's customer service and inform the display code.
3.Cleaning and Maintenance
(1) Installing Places
The working table should be smooth and avoid vibration. When the machine is placed on the working table, it should be properly rotated and emptied. The table foot should be adjusted to make it smooth. If the machine is to be moved in the future, it must be readjusted.
Indoor temperature can be normal, to avoid excessive humidity. if it is not placed in the dust-free room, you can usually cover it with a cover.
Power sockets need to load 220V, 5A or more, with grounding sockets.
(2)Cleaning
The appearance of the machine and the parts in contact with the drug must be wiped and cleaned each time the different granules are changed or replaced.
(3) Maintenance
When the machine is not in use, turn off the switch (turntable and vibrator). If the machine is not used for a long time, unplug the power cord.
After the machine is cleaned, reinstall it. And the following tests must be done before use:
① When vibrating, check whether the vibrator has a strange sound. The outlet of the
hopper should have some slight clearance with the vibrating groove, otherwise the
hopper will produce a resonance sound.
② When idling, check whether the turntable will squeak with the glass, otherwise the
glass turntable will scratch.
③ Check the lever back and forth by hand, it should be smooth and unobstructed.
Appendix
1. Configuration list of SPJ-500 Photoelectric Counting Machine:
No. | Name | Amount | Manufacturer |
01 | touchscreen | 1 | Kunlun Tongtai |
02 | frequency converter | 1 | Keken Electric |
03 | PLC | 1 | Mitsubishi |
04 | drive motor | 1 | ADDK |
05 | switch | 1 | Taihe Electric |
06 | vibration controller | 1 | COH |
07 | sensor | 1 | Fiber optic induction |
08 | tight stop switch | 1 | Taihe Electric |
09 | indicator light | 1 | Taihe Electric |
No. | Name | Specification | Manufacturer |
01 | frame | aluminum profile | Made by our company |
02 | electric box | stainless steel | Made by our company |
03 | rotating disk | tempered glass | Made by our company |
04 | hopper | stainless steel | Made by our company |