久久亚洲精品天码av,午夜福利屄插穴,午夜福利视频91,亚欧美爽爽爽爽爽,亚洲欧美日韩色色图片,青青操在线观看,精品天堂麻豆av,无码av东京热,婷婷成人亚洲少妇

官方微信|手機(jī)版|本站服務(wù)|買家中心|行業(yè)動(dòng)態(tài)|幫助

產(chǎn)品|公司|采購(gòu)|招標(biāo)

西門子室外溫度傳感器QAC31

參考價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 公司名稱山東凱拓自控技術(shù)有限公司
  • 品       牌
  • 型       號(hào)
  • 所  在  地
  • 廠商性質(zhì)代理商
  • 更新時(shí)間2025/6/16 15:08:51
  • 訪問次數(shù)341
產(chǎn)品標(biāo)簽:

在線詢價(jià) 收藏產(chǎn)品 查看電話 同類產(chǎn)品

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是 制藥網(wǎng) 上看到的信息,謝謝!

山東凱拓自控技術(shù)有限公司,主營(yíng):西門子/霍尼韋爾/國(guó)產(chǎn),電動(dòng)調(diào)節(jié)閥,溫控閥,蝶閥,壓力變送器,溫度變送器,壓力傳感器,溫度傳感器等,

西門子溫控閥,電動(dòng)閥,蝶閥,比例調(diào)節(jié)閥,壓力變送器,溫度變送器
SIEMENSSymaro™OutsideTemperatureSensors?Activesensorsforacquiringtheoutsidetemperature?OperatingvoltageAC24VorDC13
西門子室外溫度傳感器QAC31 產(chǎn)品信息
SIEMENS
18.jpg
Symaro™
Outside Temperature Sensors
Active sensors for acquiring the outside temperature
Operating voltage AC 24 V or DC 13.5...35 V
Signal output DC 0...10 V or 4...20 mA
Use
The QAC31... outside temperature sensors are for use in heating, ventilation and air conditioning plants as:
? Reference sensors for outside temperature-compensated control
? Measuring sensors, e.g. for optimization, measured value indication, or for connection to a building automation and control system
? High-end sensors for acquiring the room temperature in commercial spaces
Type summary
Type referenceMeasuring rangeOperating voltageOutput signal
QAC3161-50...+50 °CAC 24 V+20%/DC 13.5...35 VDC 0...10 V
QAC3171-50...+50 °CDC 13.5...35 V4...20 mA
Ordering and delivery
When ordering, please give name and type reference, e.g.:
Outside temperature sensor QAC3161.
The sensor is supplied complete with cable entry gland M16.
Siemens Building Technologies
HVAC Products
Equipment combinations
All systems or devices capable of acquiring and handling the sensor's DC 0...10 V or 4...20 mA output signal.
 The sensor acquires the outside temperature via its sensing element whose resistance value changes as a function of the temperature. This change is converted to a DC 0...10 V or 4...20 mA output signal, depending on the type of sensor. The output signal corresponds to the selected temperature range.
The outside temperature sensor consists of housing, printed circuit board, connection terminals and measuring probe.
The two-sectional housing is comprised of base and removable cover (screwed connection). The measuring circuit and the setting element are located on the printed circuit board inside the cover, the connection terminals on the base.
The measuring probe is screwed into the bottom of the housing.
Cable entry is either from the rear (concealed wiring) or from below (surface-run wires). For that purpose, a hole can be knocked out in the base or the enclosed cable entry gland M16 can be screwed into the bottom of the base.

The setting element is located inside the cover. It consists of 6 pins and a shorting plug. It is used to select the required measuring range and to activate the test function.
The different plug positions have the following meaning
For the temperature measuring range:
Shorting plug in the left position (R1) = 0...50 °C
Shorting plug in the mid position (R2) = -50...+50 °C (factory setting)
Shorting plug in the right position (R3) = -35...+35 °C
For activating the test function:
Shorting plug in the horizontal position: The values according to the table "Test function active" will be made available at the signal output.
In the event of fault, the output signal will reach 0 V (4 mA) after 60 seconds.
To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required. When sizing and electrically protecting the transformer, local safety regulations must be observed.
When sizing the transformer, the power consumption of the outside temperature sensor must be taken into consideration. For correct wiring, refer to the Data Sheets of the devices with which the sensor is used.
The permissible cable lengths must be observed.
When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference. Twisted pair cables are required for the secondary supply lines and the signal lines.

Mounting locationDepending on use, the outside temperature sensor must be located as follows:
? For control:
On the wall of the house or building that has the windows of the occupied rooms, but the sensor must not be exposed to the morning sun. In case of doubt, it should be mounted on the wall facing north or north-west
? For optimization:
Always on the coldest wall of the house or building (normally the wall facing north). The sensor must never be exposed to the morning sun
Mounting heightPreferably in the middle of the house or building or heating zone, but at least 2.5 m above the ground.
The sensor must not be fitted at the following locations:
? Above windows, doors, air exhausts or other heat sources
? Below balconies or the eave of the roof
To prevent measuring errors due to air circulation, the cable conduit at the sensor should be sealed.
The sensor may not be painted over.
Mounting Instructions are printed on the packaging.
Commissioning notesCheck wiring before switching on power. The temperature measuring range must be selected on the sensor, if required. 


Mounting notes

 

Technical data


Environmental conditionsOperation
Climatic conditions
Temperature (housing with electronics) Humidity
Mechanical conditions
IEC 721-3-3
class 3K5
-40...+70 °C
5...95 % r. h. (non-condensing) class 3M2

Transport
Climatic conditions Temperature Humidity
Mechanical conditions
IEC 721-3-2 class 2K3 -25...+70 °C <95 % r. h.
class 2M2
Materials and colorsBasepolycarbonate, RAL 7001 (silver-grey)

Coverpolycarbonate, RAL 7035 (light-grey)

Measuring nipplestainless steel 1.4401

Cable entry glandPA, RAL 7035 (light-grey)

Sensor (complete assembly)silicone-free

Packagingcorrugated cardboard
StandardsProduct safety Automatic electrical controls for household and similar useEN 60 730-1

Electromagnetic compatibility Immunity EmissionsEN 61 000-6-2
EN 61 000-6-3

C€ conformity toEMC Directive 89/336/EEC

G conformity to
Australian EMC Framework Radio Interference Emission Standard
Radio Communication Act 1992 AS/NZS 3548
WeightIncl. packaging QAC3161
QAC3171
approx. 0.13 kg
approx. 0.13 kg


在找 西門子室外溫度傳感器QAC31 產(chǎn)品的人還在看

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息:

托克托县| 三亚市| 大化| 乌拉特中旗| 黑水县| 五常市| 龙江县| 彭水| 蓬溪县| 济阳县| 通州区| 新营市| 安仁县| 裕民县| 连江县| 长顺县| 屏东市| 宁晋县| 金乡县| 安乡县| 教育| 萝北县| 武夷山市| 富民县| 连州市| 彩票| 望奎县| 宿州市| 义马市| 栖霞市| 汝阳县| 新丰县| 永川市| 和平县| 如皋市| 东光县| 通渭县| 垦利县| 北川| 云浮市| 鹿泉市|