The pressure loss of compressed air filter consists of
inherent pressure loss and increasing pressure loss.
The inherent pressure loss is caused by the filter shell
structure and the interface between the shell and the filter
core. The incremental pressure loss is caused by the
clogging of the filter core. Providing the optimized
compressed air channel is the key to reduce the system
operating cost.
Filter connection:The same filter has a variety of interface
sizes to choose from, and can meet both system and flowrate
requirements, increasing customer selection opportunities
and reducing installation costs.
Compact and light:ATS advanced filter core design concept
Makes filter smaller and more compact, which allow filters to
be installed even in narrow spaces.
Complete anticorrosion: ATS filter shell are all anodized,
this excellent anticorrosion performance provides 10 years
of quality assurance.
Benefits of timely replace of elements
Ensure high quality compressed air、Protection of adsorptiondryer ’s adsorption bed、Protection of downstream equipment、Reduction in operating costs、Improving productivityand profitability
What are the consequences of not replacing the filter
Will cause damaging to the adsorption bed of adsorption
dryer, resulting in unplanned replacement of the desiccant
beads、Corrosion of gas storage tanks and pipes in
transmission networks、Valves and air motors blocked and
frozen、Discharges from valves and cylinders create an
unhealthy working environment,Potential staffing attrition as
well as financial compensation due to healthissue.Machine
will be damaged,Ineffective production processes、Low
eligibility rate、Increase manufacturing cost and downtime.
The filter is equipped with a differential pressure gauge and
the pointer is in the green area, but why do we still require to
change the elements?
Reason being is that the filter fibers in the filter element
become brittle over a period of time, even a small hole can
cause the filter medium to break and thus the contaminants
will enter the downstream of the compressed air system
without filtering.If this happens, the pointer on the gauge will
always be in the green area due to the small pressure
difference between the front and back of the filter, the filter
element will not be replaced in time until the user found
contaminants downstream. Please note that even if the
element is replaced, contamination will still be remained in
the downstream pipeline for a considerable period of time.