β2糖蛋白1抗體IgA(β2-GP1AbIgA)ELISA檢測試劑盒齊一生物科技新品*,齊一生物科技長期經(jīng)營大鼠ELISA試劑盒、人elisa試劑盒,小鼠elisa試劑盒等種屬試劑盒,歡迎您訪問我們的,全國:
如有什么問題請給我們或者留言,告訴我您的需要,并留下您寶貴的意見和建議。
試劑盒名稱:β2糖蛋白1抗體IgA(β2-GP1AbIgA)ELISA檢測試劑盒
規(guī) 格:48T/96T
品牌:進(jìn)口原裝/分裝/國產(chǎn)
產(chǎn)品的用途:僅供科研究使用!
價(jià)格:電議,咨詢在線客服,到我司qysw@qiyibio.。齊一生物科技(上海)有限公司提供大量品牌進(jìn)口原裝、以及穩(wěn)定性強(qiáng)的國產(chǎn)ELISA試劑盒,性價(jià)比*歡迎您前來選購!
操作步驟
實(shí)驗(yàn)開始前,請?zhí)崆芭渲煤盟性噭?,試劑或樣品稀釋時(shí),均需混勻,混勻時(shí)盡量避免起泡。每次檢測都應(yīng)該做標(biāo)準(zhǔn)曲線。如樣品濃度過高時(shí),用樣品稀釋液進(jìn)行稀釋,以使樣品符合試劑盒的檢測范圍。
1. 加樣:分別設(shè)空白孔、標(biāo)準(zhǔn)孔、待測樣品孔??瞻卓准訕悠废♂屢?00μl,余孔分別加標(biāo)準(zhǔn)品或待測樣品100μl,注意不要有氣泡,加樣將樣品加于酶標(biāo)板孔底部,盡量不觸及孔壁,輕輕晃動(dòng)混勻,酶標(biāo)板加上蓋或覆膜,37℃反應(yīng)120分鐘。
為保證實(shí)驗(yàn)結(jié)果有效性,每次實(shí)驗(yàn)請使用新的標(biāo)準(zhǔn)品溶液。
2. 棄去液體,甩干,不用洗滌。每孔加生物素標(biāo)記抗體工作液 100μl(取1μl生物素標(biāo)記抗體加99μl生物素標(biāo)記抗體稀釋液的比例配制,輕輕混勻,在使用前一小時(shí)內(nèi)配制),37℃,60分鐘。
3. 溫育60分鐘后,棄去孔內(nèi)液體,甩干,洗板3次,每次浸泡1-2分鐘,350μl/每孔,甩干。
4. 每孔加辣根過氧化物酶標(biāo)記親和素工作液(同生物素標(biāo)記抗體工作液) 100μl,37℃,60分鐘。
5. 溫育60分鐘后,棄去孔內(nèi)液體,甩干,洗板5次,每次浸泡1-2分鐘,350μl/每孔,甩干。
6. 依序每孔加底物溶液90μl,37℃避光顯色(30分鐘內(nèi),此時(shí)肉眼可見標(biāo)準(zhǔn)品的前3-4孔有明顯的梯度藍(lán)色,后3-4孔梯度不明顯,即可終止)。
7. 依序每孔加終止溶液50μl,終止反應(yīng)(此時(shí)藍(lán)色立轉(zhuǎn)黃色)。終止液的加入順序應(yīng)盡量與底物液的加入順序相同。為了保證實(shí)驗(yàn)結(jié)果的準(zhǔn)確性,底物反應(yīng)時(shí)間到后應(yīng)盡快加入終止液。
8. 用酶聯(lián)儀在450nm波長依序測量各孔的光密度(OD值)。 在加終止液后15分鐘以內(nèi)進(jìn)行檢測。
9012140 Gripper, right, handler, BR8000
9001670 PyroMark Q24 MDx Instrument For methylation and mutation analysis using Pyrosequencing technology in 24 well CE-marked.
9001660 Rotor-Gene Q 6plex System
9001649 Rotor-Gene Q 5plex (w/o PC) PrioPLUS Rotor-Gene Q 5plex (w/o PC) PrioPLUS includes the Rotor-Gene Q system, installation and extended warranty. Installation covers hardware and software installation of system and provides user with on site introductory training. Priority package extends warranty period of the system to 3 years with shipment to Repair Center Service and response turnaround time (repair) 7-10 days. One preventive maintenance visit is included for each year of the warranty; 3 preventive maintenance visits in total. Replacement system (Loaner) provision included (provision time 2-3 days) with transportation cost coverage. The service package includes all parts, labor and travel costs with installation performance and service visits documented on a GMP/GLP-pliant Field Service documents.
9001648 Rotor-Gene Q 5plex (w/o PC) Priority Rotor-Gene Q 5plex (w/o PC) Priority includes the Rotor-Gene Q system, installation and extended warranty. Installation covers hardware and software installation of system and provides user with on site introductory training. Priority package extends warranty period of the system to 2 years with shipment to Repair Center Service has response turnaround time (repair) 7-10 days. One preventive maintenance visit is included for each year of the warranty; 2 preventive maintenance visits in total. Replacement system (Loaner) provision included (provision time 2-3 days) with transportation cost coverage. The service package includes all parts, labor and travel costs with installation performance and service visits documented on a GMP/GLP-pliant Field Service documents.
950263 Final Wash Reagent (VXF) (350 ml)
37561 Qproteome Sialic Glycoprotein Kit
133029 NeXtalStock Cesium chloride (200)
133021 NeXtalStock CABS untit. (200)
9001590 Rotor-Gene Q 6plex Platform
239025 GelPilot 50 bp Ladder (100) Ready-to-use DNA marker; 600 μl (100 lanes), 9 fragments: 50 - 500 bp
231122 QIAGEN PCR Cloning Kit (10) For 10 reactions: 2x Ligation Master Mix (50 ul), pDrive Cloning Vector (0.5 ug), distilled water (1.7 ml)
9015317 Sensor, photo, EE-SX671A
9015305 Block, elution, M48
133148 NeXtalStock BICINE pH 7.5 (200)
1037870 Buffer TLC, 2x (50/60),G
4692103 RespiFinder RG Panel RUO
1031668 Large 96-Rod Cover (16) Rod cover for use with BioSprint 96 Deep well Rod
9011958 SamTrak Rack for sixteen 12mm tubes
9243827 RCS, Basic Agreement "- Service response time RCS: 5 working days
- Inspection/maintenance delivery: yes, included; 1 /agreement year
- Cost coverage for repair parts: yes, included
- Cost coverage for labor: yes, included
- Cost coverage for travel: yes, included
- Replacement system provision for DML: yes, included
- Transportation cost coverage for DML: yes, included
For defect units, after customer calling QIAGEN technical service hotline before 12 am:
RCS:
- QIAGEN shall dispatch a specialist to repair the defect instrument at customer site within 5 working days
DML:
- A special package containing a replacement unit shall be sent to the customer within 5 working days.
- Customer shall send the defect unit to QIAGEN Regional Repair Center following the instructions attached with the packaging.
Note: for DML owned by customer, QIAGEN Regional Repair Center will send back the repaired original unit to customers within 7-10 working days.
PC, Monitor, Heater, Shaker, Washer, Printer and Votexer:
- A new unit shall be sent to customer within 7-10 working days at no extra cost
- Customer shall send the defect unit to QIAGEN for disposal
- On-site installation of PC and application software is not covered by the agreement
The Preventive Maintenance (PM) service ensures the correct operation of the equipment. During the PM, all the instrument modules are inspected by a qualified QIAGEN service technician. The Preventive Maintenance is performed under the manufacturer guidelines and documented according to GLP / GMP"
37003 #Albumin/IgG Depletion Cartridges(3x1ml)
36311 Strep-Tactin Magnetic Beads (2x1ml) For micro-scale purification of Strep-tagged proteins: 2 x 1 ml Strep-Tactin-charged magnetic agarose beads (10% suspension)
950183 Tissue Digest Reagent (DXT) (250 ml)
950047 QIAxtractor Virus Plasticware The Reagent Pack, VX, (#950407) which is used together with the Virus Plasticware Pack, QIAxtractor provides fully automated viral nucleic acid purification on the QIAxtractor. The bination of reagents and plasticware enables purification of viral nucleic acids from liquid samples, with a throughput of 8-96 samples per run.
218413 Rat miScript Primer Assay Set VX.X
9018297 EZ1 Advanced RNA Card
9018296 EZ1 Advanced DNA Buccal Swab Card
5000-1271 Y Drive Track, DML2
5000-1265 Mirror, DML2
5000-1261 PMT Socket Only, DML2
5050-1072 V.1 CD Rom Manual - V2 Software Tutorial I
5000-1508 Microplate Heater I - FuseInlet1.6A 250V
6000-5002 MST STM Rack (Black - 1 pos. cal.)
6000-4111DEV2.2 RCS User Application Manual (German)
6000-3111V2.20 RCS User Application Manual
5000-1423 Support Side 099A, VTX2
5050-2007 hc2 Software Protocol Package, CE
PK-02 Mutation Test Kit (100)
9240738 Decon tube, Water, AP98
5000-1409 Eccentric Assembly V2, VTX2
9242093 QIAxtractor, Inspection Agreement
69571 DNeasy mericon 96 QIAcube HT Kit (5)
338132 Microbial DNA-Free Water
330530 Supplemental Microbial qPCR MM (Rox)
275702 flocktype Salmonella Ab (2)
274602 flocktype Mycoplasma Ms Ab (2)
289991 virotype Tissue Lysis Reagent (25 ml)
280447 virotype BTV pan/8 RT-PCR Kit (480)
281803 virotype CSFV RT-PCR Kit (24)
9011904 ZLV Holder, disposal bag
9019517 ZLV CARRIAGE TRAN LOW SKIRT (WH)
9020030 Cable UC-20XXAB, RGQ
9020111 Tip chute, QXT
9020576 LED Assy, Red, 15" Long, DML 3000
9022132 Enclosure, careHPV
9230317 ZLV Container, WasherLiquid, 2 l
9013375 Maintenance kit, semiannual,
9013208 Screw kit, BR8000
9013203 Microplate Washer for Plato 3*** series
9013196 Tubing, vacum trap inlet auto vac,BR8000
9011703 Cable, PCON98 to AC-box (pump switch), B
800131 Publication-Ready Sequencing, w/ prep "De-novo double-stranded sequencing of plasmid DNA and PCR products
QIAGEN DNA template preparation
Data assembly and sequence alignment
Accuracy >99.99%"
12362 EndoFree Plasmid Maxi Kit (10) 10 QIAGEN-tip 500, Reagents, 10 QIAfilter Maxi Cartridges, Endotoxin-free Buffers
12162 QIAGEN Plasmid Maxi Kit (10) 10 QIAGEN-tip 500, Reagents, Buffers
10243 QIAGEN Genomic-tip 100/G 25 columns
10043 QIAGEN-tip 100 (25) 25 columns; 100 μg column capacity
4503103 artus CMV TM PCR Kit (24) RUO
133262 NeXtalStock Paratone N (200)
337623 qBiomarker SYBR Green Fluor Mastermix 24
















采購中心
