Design Directional spool valve Actuation Solenoid Size DIN NG10 / CETOP 05 / NFPA D05 Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05 Mounting position unrestricted, preferably horizontal Ambient temperature [°C] -25...+60 MTTFD value [years] 150 Weight [kg] 4.8 (1 solenoid), 6.3 (2 solenoids) Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6 30 Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 Hydraulic Max. operating pressure [bar] P, A B: 350; T: 210 (DC), 105 (AC) Fluid Hydraulic oil according to DIN 51524 Fluid temperature [°C] -20 ... +70 (NBR: -25...+70) Viscosity permitted [cSt] / [mm2/s] 2.8...400 Viscosity recommended [cSt] / [mm2/s] 30...80 Filtration ISO 4406 (1999); 18/16/13 Flow max. [l/min] 150 (DC); 115 (AC) (see shift limits) Leakage at 50 bar [ml/min] Up to 20 per flow path, depending on spool Static / Dynamic Step response see table response times Electrical characteristics Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible Max. switching frequency [1/h] 10000 Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector) Code K J U G Y T Supply voltage / ripple [V] 12 V = 24 V = 98 V = 205 V = 110 V at 50 Hz/ 120 V at 60 Hz 230 V at 50 Hz/ 240 V at 60 Hz Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5 Current consumption hold [A] 3 1.5 0.35 0.18 0.8 / 0.72 0.4 / 0.36 Current consumption in rush [A] 3 1.5 0.35 0.18 3.41 / 3.31 1.75 / 1.7 Power consumption hold [W] 36 36 34 36 88 / 86 88 / 86 Power consumption in rush [W] 36 36 34 36 375 / 397 385 / 408 Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461. Wiring min. [mm2] 3 x 1.5 recommended Wiring length max. [m] 50 recommended Technical data With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.