德國伏爾康洛克林VULKAN LOKRING Gmbh 連接管技術(shù)
德國伏爾康洛克林VULKAN LOKRING Gmbh儀表閥組 鉗子 壓縮機 連接管
:王工
同號
449147851
價注意事項:
1.請發(fā)書面詢價函(郵件,,傳真等),不接受口頭報價。
2.如果型號不能*對上,請?zhí)峁┯⑽钠放泼?具體型號+數(shù)量。
3.詢價的商友請主動告知公司名稱和,謝謝。
The theory of the LOKRING tube connection technology
The LOKRING functions according to known and proven physical rules of material nature and to technical experience. An explanation of the stress in the parts of the LOKRING joining will effect the understanding of and the absolute confidence in this method.
A LOKRING joint is made in the following manner:
The tubes are first escopically engaged with each other, then the LOKRING is placed in its starting position, i.e. the lagest internal diameter is placed on the flared tube.
 Before the assembly |
Section “A” of the LOKRING allows that the LOKRING is moved easily onto the outer tube and this outer tube is reduced during the assembly until a force fit between the parts of the tube is made. The two tubular parts are now kept in an elastic pressure position which works against the tension in the LOKRING.
The two tubes are now in intimate contact, and their diameter must now be reduced to form the actual joint.
 The joint is "made" |
The cylindrical part “B” accomodates a high flexible strength and is resistant against the torsion forces, of which the joint can be compliant.
As the LOKRING is further moved to its final assembly position, both tubes are steadily deformed by the LOKRING, whereby section “C” of the LOKRING further reduces the tubular parts with its smallest internal diameter, so the main sealing region is formed.
 Final assembly |
Equipment for production lines
For your information: on the following pages you will find a range of equipment in production lines for
evacuation and charging as well as for
testing of cooling and air conditioning systems.
The in the following shown products are individual solutions and therefore we would like to ask you to contact us for your specific requirements
Automotive Air Conditioning of VULKAN LOKRING

More than 80% of all new vehicles are now being sold with air conditioning as standard. This market is increasing and offers huge potential for garage servicing and repair.
Because of the diversity of new products offered for servicing automotive air conditioning systems it is important for garages to know which tools are necessary and best suited for their service repairs.
Based on our more than 25 years of experience in the air conditioning field we offer a high quality range of tools for all the important service repairs on automotive air conditioning systems. VULKAN LOKRING has established a world wide network of representative offices. Thus we can offer you a first-class, in situ service – wherever your location. An experienced team of engineers ensures that we only offer products which really meet the highest of requirements. Our world wide supply management ensures that our prices are competitive and in line with the market.
We hope that you will continue to profit from all these benefits, and allow us to continue our mutually successful co-operation!
You find at VULKAN LOKRING the following products for the Automotive Air Conditioning:
A/C Service Station SpeedMaxx
LOKRING: Tube Repair
Hose Repair
Leak Detection
A/C Service
Diagnosis
Evaporator Cleaning
Spring-Lock Tools
Flushing
Refrigerant and Oil
Tools and Accessories
Consumables
LOKRING Gmbh儀表閥組 鉗子 壓縮機 連接管
產(chǎn)品系列:
Evacuation and charging
| VPSdigital Evacuation- and charging station | |
The automatic evacuation and charging station for easy installation and maintenance of A/C domestic and industrial refrigerant circuits. Complex processes such as evacuation, leak test and exact charging are compley automatic and monitored by the programmable control unit. The user-friendly software facilitates the proper execution of the job by clear instructions. Due to the digital linkage of vacuum pump, charging scale and test equipment the professional working and handling of today´s refrigerants becomes safer and more environment-friendly. The VPSdigital display shows all those individual values which will be indicated otherwise separay from test manifold, vacuum gauge and charging scale. |
- Simple handling
- Easily transportable
- Automatic and supervised processes
- Evacuation and charging
- Leak detection
- Diagnosis
- Software in several languages
- On-board-printer
- Internal scale: 5kg (+/- 1g)
- External socket for 100kg scale (+/- 10g) (WP100)
- Additional protective contact socket
Technical data: - Power supply: 230V/50Hz/1Ph
- Displacement: 2.5 cfm
- Final partial pressure (abs): 0.01 mbar
- Connection: 1/4” SAE
- LCD
Special features: - Hose length HP & LP: 2400mm
- High vacuum sensor: 0-15psi
- 2 high pressure sensors: 15-500psi
- Bottle & circuit adapters:
2 x 1/4” SAE-M - 5/16” SAE-F (R410A) 2 x 16-C 1 x W21,8-14 1 x W21,8-14L 1 x EV-12 1 x HFFB-1
Options: - External scale: 100kg
- Heating belt: 400W
(Ø 250mm, h=80mm) - Heating belt: 1000W
(Ø 300-400mm, h=200mm) - Protective gloves
- Protective goggles
| 
|
| Article-No. | Article | Description | Weight (kg) | Dimensions (LxBxHmm) | | L13003815 | VPSdigital | Evacuation- and charging station | 25 | 430x400x370 | | L13003816 | WP100 | External weighingplatform 100kg | 4,3 | 260x260x60 | | L14001885 | HM400 | Heating belt 400W | 0,5 | | | L15002089 | HM1000 | Heating belt 1000W | 3 |
|
Gauges and manifolds
Adjustable, vibration-free low pressure, high pressure or vacuum gauges with radial connection. Technical data - Diameter: 80mm
- Connection: 1/8” NPT
- Quality grade 1.0
|  |
| Articel-No. | Article | Refrigerant | Scale (bar) | | L14000690 | MN-01 | R600a | -1 / 3 | | L14000691 | MN-02 | R407C / R404A / R134a / R22 | -1 / 15 | | L14000692 | MN-03 | R502 / R22 / R12 | -1 / 10 | | L14000693 | MN-04 | R600a / R22 / R290 | -1 / 10 | | L14000694 | MN-05 | R507 / R404A / R134a | -1 / 15 | | L14000695 | MN-06 | R12 / R134a | -1 / 10 | | L14000696 | MN-07 | R134a | -1 / 10 | | L14000779 | MN-08 | R410A | -1 / 30 | | L14002025 | MN-09 | R413A | -1 / 10 | | Articel-No. | Article | Refrigerant | Scale (bar) | | L14000697 | MH-01 | R600a | -1 / 10 | | L14000698 | MH-02 | R407C / R404A / R134a / R22 | -1 / 35 | | L14000699 | MH-03 | R502 / R22 / R12 | -1 / 30 | | L14000700 | MH-04 | R600a / R22 / R290 | -1 / 30 | | L14000701 | MH-05 | R507 / R404A / R134a | -1 / 35 | | L14000702 | MH-06 | R12 / R134a | -1 / 30 | | L14000703 | MH-07 | R134a | -1 / 30 | | L14000778 | MH-08 | R410A | -1 / 50 | | L14002024 | MH-09 | R413A | -1 / 30 |
|
| | |
| Vacuum gauge | |
| Articel-No. | Article | Scale (mbar) | | L14000704 | V80 | 0 / 1000 |
|  |
Pliers
Piercing pliers AZ-027K Piercing pliers EZ-LC Pinch-off pliers KZ-008 Tube cutting pliers LRSZ Capillary tube cutting pliers CTP-1 |
| | |
Piercing pliers AZ-027K For recovering refrigerant from damaged but still pressurised cooling systems. For driers and copper tubes up to an outside diameter of 6, 8 and 10mm (1/4”, 5/16” and 3/8”). Hose connection: 1/4” SAE Supplied in a synthetic case. top |  |
| Article-No. | Article | Description | | L13001976 | AZ-027K | Piercing pliers | | L14000211 | AZ-027A | Replacement piercing pin | | L14000212 | AZ-027B | Replacement gasket | | L14000370 | AZ-027C | Gasket for piercing pin | | L14000651 | AZ-027D | Insert 1/4'' | | L14000654 | AZ-027E | Insert 5/16'' | | L14000655 | AZ-027F | Insert 3/8'' | | L13002439 | AZ-027G | Complete set of inserts (consists of each one 1/4”, 5/16” and 3/8” insert) |
|
| | |
Piercing pliers EZ-LC For recovering refrigerant from damaged but still pressurised cooling systems. For copper tubes with an outside diameter of 6mm (1/4”). Hose connection: 1/4” SAE top |  |
| Article-No. | Article | Description | | L14003017 | EZ-LC | Piercing pliers | | L14003018 | EZ-LC-E | Replacement piercing pin | | L14003019 | EZ-LC-D | Replacement gasket |
|
| | |
Pinch-off pliers KZ-008 For pinching-off charging tubes without schrader valves up to an outside diameter of 10mm (3/8”). top |  |
| Article-No. | Article | | L14000201 | KZ-008 |
|
| | |
Tube cutting pliers LRSZ For cutting copper, aluminium and steel tubes with an outside diameter of 4 up to 13mm (1/8” up to 1/2”) and a wall thickness of up to 1.5mm. A 120° rotation is sufficient for the cutting. The tool ensures clean, right-angled cuts even directly at the soldering point. top |  |
| Article-No. | Article | Description | | L14000166 | LRSZ | Tube cutting pliers | | L13001304 | LRSM | Cutting wheel |
top |
| | |
| Capillary tube cutting pliers CTP-1 For a perfect cutting of capillary tubes without closing of the internal diameter. Suitable for all capillary tube diameters. |  |
| Article-No. | Article | | L14000005 | CTP-1 |
|
壓縮機
Compressors
For refrigerators and freezers. Compressors are complete with all electrical parts, rubber feet and evaporator water tray. Compatible to other compressors (see cross compatibility table). Power supply: 230V/50Hz |
| Article-No. | Article | HP | Cooling capacity (kcal/h) / (Watt) | Displacement (cm3) | nom. Power consumption (Watt) | Dimensions (HxBxTmm) | Weight (kg) | | R134a | | L14000506 | Compressor 1/3 PS R134a | 1/3 | 217 | 252 | 9,27 | 188,8 | 220x230x150 | 11,0 | | L14000480 | Compressor 1/4 PS R134a | 1/4 | 153 | 178 | 8,07 | 164,8 | 200x230x160 | 10,3 | | L14000479 | Compressor 1/5 PS R134a | 1/5 | 157 | 183 | 8,40 | 143,5 | 210x240x160 | 9,8 | | L14000478 | Compressor 1/6 PS R134a | 1/6 | 123 | 140 | 5,61 | 116,1 | 180x210x150 | 7,8 | | L14000477 | Compressor 1/8 PS R134a | 1/8 | 88 | 102 | 4,15 | 89,0 | 170x210x150 | 7,2 | | L14000849 | Compressor 1/10 PS R134a | 1/10 | 64 | 74 | 3,40 | 73,7 | 170x230x140 | 7,1 | | R600a | | L14000485 | Compressor 1/4 PS R600a | 1/4 | 201 | 234 | 14,30 | 161,7 | 220x250x180 | 10,7 | | L14000484 | Compressor 1/5 PS R600a | 1/5 | 171 | 199 | 12,30 | 143,2 | 220x250x180 | 10,7 | | L14000483 | Compressor 1/6 PS R600a | 1/6 | 123 | 143 | 8,87 | 113,0 | 180x220x150 | 7,7 | | L14000482 | Compressor 1/8 PS R600a | 1/8 | 92 | 107 | 6,67 | 79,3 | 170x230x150 | 7,1 | | L14000481 | Compressor 1/10 PS R600a | 1/10 | 73 | 85 | 5,19 | 70,7 | 190x230x160 | 7,1 |
|
| | |
| Cross compatibility table |
LOKRING- Article | Aspera | Danfoss | Electrolux | Matsushita | Embraco | | R134a | | Compressor 1/3 PS R134a | NE1121Z | NLE9F | | DA91... | FGV110HA FGS90AH FGS100HA | | Compressor 1/4 PS R134a | NB1118Z | NLE9F NL9F | GL90AH GL90AA GL90AB | DA91... | FGS90HA | | Compressor 1/5 PS R134a | NB1116Z | NLE7F NL7F | GL80AH GL80AA GL80AB | DA77... | FGV80HA | | Compressor 1/6 PS R134a | BPM1111Z | TLES5F TLS5F | GL60AH GL60AB GL50AH GL50AA | SB51C... D51... | EMI55H... EMI50H... | | Compressor 1/8 PS R134a | EMT36HLP | TLES4F TLS4F | GL45AH GL45AB GL40AH GL40AA | SB43C... | EMI40H... | | Compressor 1/10 PS R134a | BPM1072Z | TLES3F TLS3F | GD40AA GL35AB GD30AA | SB35C... SB30C... | EMI30H... | | R600a | | Compressor 1/4 PS R600a | NBM1118Y | NLE15K NL15K | HP16AH | | | | Compressor 1/5 PS R600a | NBM1116Y | NLE13K NL13K | HP14AH | DA135E | | | Compressor 1/6 PS R600a | BPK1111Y | TLES9K TLS9K | HL99AH HL99AA HL90AH HL90AA | | FGV60CA FGS60CA FGV50CA FGS50CA | | Compressor 1/8 PS R600a | BPK1084Y | TLES7K TLS7K | HL70AH HL70AA HL67AH | SD65E | EMI40CEP EMI40CSC | | Compressor 1/10 PS R600a | EMT26CLP | TLES6K TLS6K | HL67AA HL60AA | | EMI30CEP EMI30CSC |
|
| | | Home > Products > LOKRING for appliance service |  | | | Tube joinings for the service fieldTechnical Information Features of the LOKRING tube connection Permanent hermetically metal-to-metal sealing Unproblematical connection of tubes consisting of different materials High reliability No special preparation of the tubes necessary Easy and fast assembly Handy assembly tools Great tolerances in dimensions are allowed No notch effect in the assembly area No welding, soldering or screw cutting Ecologically careful and harmless system Pressure and temperature area The LOKRING connections are designed for a working pressure of 50bar (depending on the tube material) with fourfold security and for the range of temperature from -50°C up to 150°C (-58°F up to 302°F). Material affiliation LOKRING tube connections are made out of the materials aluminium and brass. LOKRING brass connections for tube diameter ≥ 9.53mm (3/8”) are connected by steel LOKRINGs (galvanically thinned and chromated). The affiliation of the LOKRING material depends on the material of the tubes to be connected. Closer information you will find under the point Application field of the LOKRING-tube connections. Tube joinings for the service field We would like to point out that LOKRING connections for the following connection diameters can also be used for further tube diameters: | Connection diameter | suitable for tube diameter | Mark at the outside diameter of the ring by: | | 1.6mm | 1.6mm / 1.7mm | 1 groove | | 1.8mm | 1.8mm | 3 grooves | | 2.0mm | 1.9mm / 2.0mm | no grooves | | 2.2mm | 2.2mm / 2.3mm | 2 grooves | | 2.5mm | 2.4mm / 2.5mm | no grooves |
|
|