詳細(xì)介紹
瑞士Elpro-Buchs AG 傳感器 數(shù)據(jù)采集儀
瑞士Aquasant AG傳感器
德國(guó)SECATEC electronic GmbH 傳感器
德國(guó)OPTOcon AG傳感器
產(chǎn)品系列:
:王工
同號(hào)
449147851
價(jià)注意事項(xiàng):
1.請(qǐng)發(fā)書面詢價(jià)函(郵件,,傳真等),不接受口頭報(bào)價(jià)。
2.如果型號(hào)不能*對(duì)上,請(qǐng)?zhí)峁┯⑽钠放泼?具體型號(hào)+數(shù)量。
3.詢價(jià)的商友請(qǐng)主動(dòng)告知公司名稱和,謝謝。
OEM-Board
Measure 100 x 160 x 40 mm
Weight 450g
Power input 9-12 Volt, 450mA
Measurement range 0-300°C, others on request, RS232 for datalogging, Analogout 4-20 mA or 0-10 Volt.
| FOTEMP1-OEM-Box is a fiberoptical one-channel thermometer for temperature measurement in high electromagnetic interfered environment. It is suitable for the installation in e.g. microwave applications or drying furnaces. Due to the compact design upgrading or retrofitting is possible into already existing series. With the integrated RS-232 interface or the BNC analogue output (0-10V) regulation also possible for complex temperature gradients. The fiber optic probe consists of a GaAs (gallium arsenide) probe tip, which is compley non-metallic. Length of the probe is 1m, different probe lengths and configurations on request. Area of application lies between 0°C und 300°C.
|
inductive sensors

- starting at Ø 3mm
- DC-, Namur- and AC-versions
- plug or cable connection
- normally open, normally closed, antivalent output
- 2-, 3- und 4-wire technology
- stainless steel, brass-, plastic housings
- short circuit protection/reverse battery protection/overload protection
- pressure resistant sensors up to 300 bar
- special designs on request
- catalogue inductive standard

- datasheets inductive standard
capacitive sensors

- starting at size M12
- plug or cable connection
- normally open, normally closed output
- stainless steel, brass-, plastic housings
- short circuit protection/reverse battery protection/overload protection
- special designs on request
- catalogue capacitive standard

- datasheets capacitive standard
top of page
magnetic switches for general applications
heat-resistant magnetic switches

- normally open, normally closed, change-over contact, bistable as well
- high vibration resistance
- LED indicator
- special designs on request
- heat-resistant versions
- catalogue magnetic switches general standard

- datasheets magnetic switches general standard
- catalogue heat-resistant magnetic switches

- datasheets heat-resistant magnetic switches
top of page
magnetic switches for elevators

- normally open, normally closed, change-over contact, bistable as well
- plug or cable connection
- LED indicator
- special designs on request
- catalogue magnetic switches for elevators standard

- datasheets magnetic switches for elevators standard
top of page
sensors for cylinders

- 2- and 3-wire reed contact, electronic versions as well
- plug or cable connection
- LED indicator
- special designs on request
- catalogue sensors for cylinders
standard
- datasheets sensors for cylinders standard
top of page
level sensors

- potential-free
- robust and wearless
- high repeat accuracy
- selectable tube length up to 2m
- free selectable number and position of switch-points
- acid-proof versions available
- plug or cable connection
- catalogue level sensors standard

- datasheets level sensors standard
top of page
-approved magnetic switches, burst sensors

- normally open, normally closed, change-over contact, bistable as well
- miscellaneous designs
- cable connection
- catalogue Ex-approved magnetic switches, burst sensors standard

- datasheets Ex-approved magnetic switches, burst sensors standard
- ATEX-approvals
conformity of the construction method: KEMA 06ATEXQ0012

MKR13X...: KEMA 02ATEX1288 X
MKF19X...: KEMA 02ATEX1248 X
GKR18X...: KEMA 02ATEX1248 X
GKR18X...: KEMA 03ATEX2102 X
GMG12O...: IBExU05ATEX1035
MMG12O...: IBExU06ATEX1030
- IECEx-approvals
Quality Assessment Report: NL/KEM/QAR07.0016/00
MKR13X.AK: IECEx KEM 08.0009 X
MKF19X.AK: IECEx KEM 08.0009 X
GKR18XSAK: IECEx KEM 08.0009 X
GKR18XUAK: IECEx KEM 08.0009 X
top of page
other sensors and equipment
- on request:
hybrid circuit technology
electronic position detection
angle sensors
accessories
Sensor Type AF21
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -190°C to 350°C | |
| Ambient temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 20 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | max. 1000mm | |
| Material wet side: | 1.4435, Quartz-Glass | |
| Control system types: | AS1, AS8, AS9, AN3, AN9, AS51-E24 | |
| Inline sterilization possible | ||
- Main area of applications: High-/low alarm, overfill safety device, leakage control in refineries, distilleries, pump control, offshore, protection against unlubricated operation, tanker vessels, acid storage, pharmaceutical- and chemical industry
- Liquid/Media: Liquid fuel, LPG, acids, mineral oil etc.
PDF AF21 Datasheet
Sensor Type AF42
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 20 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, Quartz-Glass | |
| Control system types: | AS1, AS8, AS9, AN3, AN9, AS51-E24 | |
| Inline sterilization possible | ||
- Main area of applications: Low alarm (fail save) in process industry, LPG caverns, refineries, tank farms, acid production, pharmaceutical and chemical industry etc.
- Liquid/Media: Liquid fuel, LPG, oil, beer, wine, palm oil, acid, solvent etc.
PDF AF42 Datasheet
Sensor Type AF33 (fibre-optic technology)
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 20 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1"/ Flange DIN/ANSI | |
| Mounting length: | max. 3185 mm | |
| Material wet side: | 1.4435, Quartz-Glass | |
| Control system types: | AS1, AS8, AS9, AN3, AN9, AS51-E24 | |
| Inline sterilization possible | ||
Due to fibre-optic technology no lightning protection necessary!
- Main area of applications: High-/low alarm, overfill safety device, leakage control in refineries, distilleries, pump control, offshore, protection against unlubricated operation, tanker vessels, acid storage, pharmaceutical- and chemical industry
- Liquid/Media: Liquid fuel, LPG, acid, mineral oil, solvent, vegetable /animal oil in food industry, beverage production, various fluids in laboratories and hospitals etc.
PDF AF33 (fibre-optic technology) Datasheet
Sensor Type AF1S
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 70°C | |
| Operating pressure: | -0.5 bar to 7bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | Polyamide 66, Duran Glass | |
| Control system types: | AS1, AS8, AS9, AN3, AN9, AS51-E24 | |
- Main area of applications: High alarm, overfill safety device, leakage control
- Liquid/Media: Mineral oils, fuels, water purification
PDF AF1S Datasheet
Sensor Type AF6
| Technical data | ||
| Operating temperature: | -30°C to 70°C | |
| Operating pressure: | -0.5 bar to 7bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | Polyamide 66, Duran Glass | |
| Control system types: | AS6.1, AS6.2, AS6.3, AS6.4 | |
- Main area of applications: High alarm, Overfill safety device, Leakage control
- Liquid/Media: Caustic solution, various oils, liquids in the food-/beverage industry- and animal fodder industry etc.
PDF AF6 Datasheet
Sensor Type AF23
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 20 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1"/Flange DIN/ANSI | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, Duran-Glass | |
| Control system types: | AS1, AS8, AS9, AN3, AN9, AS51-E24 | |
| Inline sterilization possible | ||
- Main area of applications: High-/low alarm, leakage monitoring in refineries and tank farms, distilleries, offshore, acid production, pharmaceutical- and chemical industry, laboratories, overfill safety device on tanker vessels, production- and racking plants in beverage industry, protection against unlubricated operation for gas-compressors and turbines etc.
- Liquid/Media: Liquid fuel, LPG, oil, beer, wine, palm oil, acid, solvent etc.
PDF AF23 Datasheet
Sensor Type AFS11 (with integrated self-monitoring evaluation)
| Technical data | ||
| Supply voltage: | 24V AC/DC ±20% | |
| Power: | app. 0.6VA (15mA to 30mA) | |
| Relay circuit: | max. 50mA / 30V AC/DC / 0.45W | |
| Insulation voltage: | 750V AC 1min. | |
| Operating temperature: | -25°C to 75°C | |
| Operating pressure: | -0.5 to 7 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | Polyamide 66, Duran-Glass | |
The short-circuit proof output of the AFS11 Level sensor can be connected directly to a PLC.
- Main area of applications: High alarm, leakage monitoring, overfill safety devices
- Liquid/Media: Mineral oils, fuels, water purification etc.
PDF AFS11 Datasheet
Sensor Type AFS12 (with integrated self-monitoring evaluation)
| Technical data | ||
| Supply voltage: | 24V AC/DC ±20% | |
| Power: | app. 0.6VA (15mA to 30mA) | |
| Relay circuit: | max. 50mA / 30V AC/DC / 0.45W | |
| Insulation voltage: | 750V AC 1min. | |
| Operating temperature: | -25°C to 75°C | |
| Operating pressure: | -0.5 to 7 bar | |
| Self monitoring: | yes | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, Duran-Glass | |
The short-circuit proof output of the AFS12 Level sensor can be connected directly to a PLC.
- Main area of applications: High alarm, leakage monitoring, overfill safety devices
- Liquid/Media: Chemicals, acid, solvent, vegetable /animal oil in food industry, beverage production, various fluids in laboratories and hospitals etc.
PDF AFS12 Datasheet
Control Systems
Control system Type AS9-E24 (two wire technology)
| Technical data | ||
| *Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 24V AC/DC ±10% | |
| Relay contacts: | max. 0.5A, max. 48VAC, max. 50VA | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo:7.2V, lo:<68mA, Co:<14, 5µF, Lo:<6Mh | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% | |
| Type of protection: | IP20 | |
| Dimensions: | European standard board 100 x 160mm | |
| Output: | 2 potential-free change-over contacts | |
Options:
Type VE9 local electronic
To be operated with sensor type: AF24, AF26, AF31, AF32, AF36
*With local electronic type VE9 to be used in [EEx ia] IIC environment together with sensor types: AF1S, AF21, AF23, AF33, AF35, AF42.
The control system AS9-24 offers high disturbance immunity for long (up to 1500m) cable installations.
Controls:
Test button for the functional inspection of the appropriate sensor and the control system.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AS9-E24 Datasheet
Control system Type AS1
| Technical data | ||
| Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 230V ±10%, 50Hz | |
| Relay contacts: | max. 1A, max. 250VAC, max. 250VA | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo :7.2V, lo:77mA, Co:14, 5µF, Lo:6mH | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% | |
| Type of protection: | IP54 | |
| Dimensions: | HxD: 132x71x137mm | |
| Output: | 2 potential-free change-over contacts | |
Options: Type AS1.2 with acoustic alarm
To be operated with sensor types: AF1S, AF21, AF23, AF33, AF42
Controls:
Test button for the functional inspection of the appropriate sensor and the control system. Reset key for the acknowledgement of the acoustic alarm. Relay output remains on alarm.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, failure in the connection cable, or fault in the control system.
PDF AS1 Datasheet
Control system Type AS6
| Technical data | ||
| Auxiliary voltage: | ||
| Type AS6.1/AS6.2: | 230V ±10%, 50Hz | |
| Type AS6.3/AS6.4: | 24VAC/DC ±10% | |
| Relay contacts: | max. 1A, max. 250VAC, max. 100VA | |
| Opto electronic coupler: | 5..24VDC, 10mA +10% | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo :7.2V, lo:82mA | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% Type AS6.2/6.4: 0.5 to 10 sec. -10 ...+50% | |
| Type of protection: | IP54 | |
| Dimensions: | HxD: 77x39x92 mm | |
To be operated with sensor type: AF6
Controls:
Test button for the functional inspection of the appropriate sensor and the control system. Type AS6.2 and AS6.4 cover the option to adjust the sensitivity as well as the response delay of the sensor.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AS6 Datasheet
Control system Type AN3
| Technical data | ||
| *Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 230V ±10%, 50Hz | |
| Relay contacts: | max. 1A, max. 250VAC, max. 250VA | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo:7.2V, lo:89mA, Co:13, 5µF, Lo:5mH | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% | |
| Type of protection: | IP54 | |
| Dimensions: | HxD: 132x71x137 mm | |
| Output: | 2 potential-free change-over contacts (with hold fuction) | |
To be operated with sensor type: AF24, AF26, AF31, AF32, AF36
*For operation in [EEx ia] IIC T4 environment: Operate with sensor type: AF1S, AF21, AF23, AF33, AF35, AF42.
Controls:
Test button for the functional inspection of the appropriate sensor and the control system.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AN3 Datasheet
Control system Type AS8
| Technical data | ||
| Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 230V ±10%, 50Hz | |
| Relay contacts: | max. 1A, max. 250VAC, max. 250VA | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo:7.2V, lo:89mA, Co:13, 5µF, Lo:5mH | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% | |
| Type of protection: | IP54 | |
| Dimensions: | HxD: 132x71x137 mm | |
| Output: | 2 resp. 3 potential-free change-over contact | |
Options:
Type AS8.2: With two sensor circuits and two potential free change-over contacts.
Type AS8.3: With three sensor circuits and three potential free change-over contacts.
To be operated with sensor type: AF1S, AF21, AF23, AF33, AF42
Controls:
Test button for the functional inspection of the appropriate sensor and the control system.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AS8 Datasheet
Control system Type AS9 (two wire technology)
| Technical data | ||
| *Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 230V ±10%, 50Hz | |
| Relay contacts: | max. 1A, max. 250VAC, max. 250VA | |
| Sensor circuitry: | (intrinsically safe, self monitoring) Uo:7.2V, lo:133mA, Co:13, 5µF, Lo:1.3mH | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | 1 sec. ±50% | |
| Type of protection: | IP54 | |
| Dimensions: | HxD: 132x71x137 mm | |
| Output: | 1, 2 or 3 potential-free change-over contacts | |
Options:
Type AS9.1: with one potential free change-over contact.
Type AS9.2: with two potential free change-over contacts.
Type AS9.3: with three potential free change-over contacts.
Type VE9: Local electronic
To be operated with sensor type: AF24, AF26, AF31, AF32, AF36
*With local electronic type VE9 to be used in [EEx ia] IIC T4 environment together with sensor types: AF1S, AF21, AF23, AF33, AF35, AF42.
The control system AS9 offers high disturbance immunity for long (up to 1500m) cable installations.
Controls:
Test button for the functional inspection of the appropriate sensor and the control system.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AS9 Datasheet
Control system Type AS51-E24 / AS83-E24
| Technical data | ||
| *Ex-classification: | [EEx ia] IIC | |
| Auxiliary voltage: | 24V AC/DC ±10% | |
| Relay contacts: | max. 0.5A, max. 48VAC, max. 50VA | |
| Sensor circuitry: | (intrinsically safe self monitoring) Uo:7.2V, lo:<68mA, Co:<14, 5µF, Lo:<6mH | |
| Temperature range: | -20°C to 40°C | |
| Response delay: | Type AS51-E24: 1 sec. ±50% Type AS83-E24: 0.5 to 20 sec. ±50% | |
| Type of protection: | IP20 | |
| Dimensions: | European standard board 100 x 160mm | |
| Output: | 2 potential-free change-over contacts | |
Options:
Type VE9:Local electronic
To be operated with sensor type: AF23, AF26, AF31, AF32, AF36
*For the use in [EEx ia] IIC environment together with sensor types: AF1S, AF21, AF23, AF33, AF35, AF42.
Controls:
Test button for the functional inspection of the appropriate sensor and the control system.
Type AS83-E24 covers the option to adjust the sensitivity as well as the response delay of the sensor.
Self monitoring:
The patented self-monitoring triggers an alarm in case of malfunction of the sensor, a failure in the connection cable, or a fault in the control system.
PDF AS51-E24 Datasheet
PDF AS83-E24 Datasheet
«
Conductance Probes
Conductance Probes Type LS11, LS12
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 5 bar | |
| Mounting connection: | Shackle | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, PTFE | |
| Control system types: | AS9, AN9, AS9-E24 | |
- Main area of applications: Pump control, pump-well pool, hollow-space monitoring for tanks. Interface applications for oil / water or conducting / non-conducting.
- Liquid/Media: oil/water
PDF LS11 Datasheet
PDF LS12 Datasheet
Conductance Probes Type LS13
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 5 bar | |
| Mounting connection: | G1" | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, PTFE | |
| Control system types: | AS9, AN9, AS9-E24 | |
- Main area of applications: Pump control, pump-well pool, hollow-space monitoring for tanks. Interface applications for oil / water or conducting / non-conducting.
- Liquid/Media: oil/water
PDF LS13 Datasheet
Conductance Probes Type LS21
| Technical data | ||
| Ex-classification: | EEx ia IIC T4 | |
| Operating temperature: | -30°C to 80°C | |
| Operating pressure: | -0.5 to 5 bar | |
| Mounting connection: | Shackle | |
| Mounting length: | according to customer spec. | |
| Material wet side: | 1.4435, Kynar | |
| Control system types: | AS9, AN9, AS9-E24 | |
- Main area of applications: Oil separators, pool monitoring for tank-storage facilities and underground tanks, etc. Interface applications (layers of approx. 3mm) oil / water or conducting / non-conducting, following the level, lift height of 500mm.
- Liquid/Media: Oil/water
PDF LS21 Datasheet
![]() | ![]() | ![]() | ![]() | ![]() | |||||||
![]() | |||||||||||
| LIBERO PDF Logger® The stand-alone datalogger for cold chain monitoring. More... | Central Monitoring System Security for regulated environments. More... | ECOLOG-NET networkable dataloggers The LAN / W-LAN network datalogger series. More... | ECOLOG dataloggers Measures, stores and documents temperature and relative air humidity values. More... | ECOLOG EEx dataloggers All products of the ECOLOG family for locations with explosion hazard zone 1. More... | |||||||
![]() | |||||||||||
![]() | ![]() | ![]() | ![]() | ||||||||
![]() | |||||||||||
| HOTDOG & HAMSTER-A dataloggers Fully welded unit, well tried and reliable. More... | HAMSTER-E dataloggers The little datalogger for temperature and air humidity. More... | HOTBOX SE dataloggers For temperatures and DC / mA signals; for pressure, gases, current, speed etc. More... | HOTBOX dataloggers For technical measurements up to 1200°C or high temperature humidity. More... | ||||||||
![]() | |||||||||||
![]() | ![]() | ![]() | ![]() | ![]() | |||||||
![]() | |||||||||||
| LIBERO Configuration Utility Free utility for LIBERO PDF Logger®. More... | elproLog SUITE Software For all Windows systems. Compliant to GLP / GMP / GAMP. More... | elproLog ANALYZE and ANALYZE QLS PC evaluation software for ELPRO Datalogger systems. More... | elproLog MONITOR and WebAccess Real-time display of readings and alarms. More... | elproLog EVENT Central audit trail for all ELPRO software components. More... | |||||||
![]() | |||||||||||
![]() | ![]() | ||||||||||
![]() | |||||||||||
| elproLog USER Configuration of the Datalogger Network. More... | elproLog CONFIG Configuration of the Datalogger Network. More... | ||||||||||
![]() | |||||||||||
![]() | ![]() | ![]() | |||||||||
![]() | |||||||||||
| Sensors Temperature probes for PT100, NTC and type K dataloggers. More... | Accessories Mounting fixtures, alarm devices and specials. More... | Q-tag 2 Second generation of alarm monitors. More... |
| |||||||||||||||||||||||
![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||
![]() |
| ||||||||||||||||||||||
| Datalogger evaluation without any software! The independent PDF Logger® revolutionizes cold chain monitoring With the LIBERO PDF Logger®, you require only one single device and no specific software to monitor temperature during the global transfer of goods to respective destinations. The LIBERO can be plugged into the USB interface of any PC to automatically generate a PDF file which can be read anywhere without difficulty. The ELPRO LIBERO is the first PDF datalogger in the world which complies with the ISO Standard 19005-1-Document Management. Easiest handling
![]() | |||||||||||||||||||||||
制藥網(wǎng)









Download Datasheet

























制藥網(wǎng)
青冈县|
交口县|
宁晋县|
镇沅|
江门市|
长沙市|
白山市|
额济纳旗|
绥芬河市|
忻城县|
当涂县|
北辰区|
南澳县|
大安市|
安陆市|
蒙自县|
肇东市|
万年县|
武穴市|
溆浦县|
文山县|
通州市|
柳州市|
邵阳县|
安化县|
东阿县|
鄂州市|
巢湖市|
湘乡市|
凌源市|
安康市|
镇原县|
石泉县|
安龙县|
北流市|
怀远县|
左权县|
贺州市|
辽阳县|
钦州市|
江华|