久久亚洲精品天码av,午夜福利屄插穴,午夜福利视频91,亚欧美爽爽爽爽爽,亚洲欧美日韩色色图片,青青操在线观看,精品天堂麻豆av,无码av东京热,婷婷成人亚洲少妇

第三方登錄
官方微信

制藥網(wǎng)>產(chǎn)品展廳>儀器儀表>其它儀器儀表>其它儀器儀表> MET/TEMP II Temperature Calibration...

  • MET/TEMP II Temperature Calibration Software v5.1
舉報(bào) 收藏
參考價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
品牌

廠商性質(zhì)

其他

型號(hào)

訪問(wèn)次數(shù)

151

產(chǎn)地

上海

更新時(shí)間

2025/9/26 8:08:24

聯(lián)系時(shí)請(qǐng)說(shuō)明來(lái)自制藥網(wǎng)!
在線詢價(jià)

請(qǐng)?zhí)顚懖少?gòu)的儀器名稱!

接受(1-3家)

產(chǎn)品簡(jiǎn)介

MET/TEMPIIsoftwareenablesyoutoeasilyautomatethecalibrationonawiderangeoftemperaturesensors

MET/TEMP II Temperature Calibration Software v5.1詳細(xì)信息

MET/TEMP II software enables you to easily automate the calibration on a wide range of temperature sensors. It provides a comprehensive temperature calibration solution for testing batches of sensors, calculating characterization coefficients and printing calibration reports. You can standardize comparison or fixed point calibrations, and use multiple temperature sources or references in a single test. Version 5.1 updates the popular MET/TEMP II software by offering compatibility with the Microsoft Windows® 7, 8 and 10 operating systems and including support for the 6109A and 7109A Portable Calibration Baths, the 1586A Super-DAQ Precision Temperature Scanner, and multiple COM ports without a SmartSwitch.

Key features and benefits

Fully automated, consistent sensor calibration

MET/TEMP II fully automates batch calibrations of your platinum resistance thermometers (PRTs), thermistor and thermocouple sensors, freeing your time for more important tasks. You can be confident your results are consistent no matter who does the job since MET/TEMP II monitors and controls the calibration process.

Test a broad workload of temperature sensors

MET/TEMP II handles a wide range of temperature sensors. It can calibrate thermocouples, RTDs, SPRTs, thermistors, and even liquid-in-glass (LIGs), bi-metallic thermometers, and connected sensors that can’t be attached to a readout. Virtually any sensor with a resistance or voltage output can be tested, up to 100 sensors at a time. They don’t even have to be the same type. You can select up to 40 temperature points for testing your sensors.

Multiply your lab productivity

Manual temperature sensor calibration is expensive, time consuming, and error prone. It takes roughly four hours to calibrate a sensor at three points, then another hour for paperwork to document the temperature data and to create the certificate. And your results may vary depending on the technician doing the calibration. There’s a better way.

With MET/TEMP II software, simply place your test sensors in a heat source, connect them to a temperature readout, enter your setup information, and start the test. Later print out the reports, sign them, and ship the sensors back to your customer. You and your customers will love the fast turnaround. It’s your choice. Spend hours handling temperature sensor calibration manually. Or get consistent, repeatable measurements in just minutes with MET/TEMP II.

Proven, trusted calibration software

MET/TEMP II v5.1 is an updated version of trusted, well-known software that easily connects to your Fluke Calibration equipment. Hundreds of customers worldwide use this software in their calibration labs. Version 5.1 maintains the structure and work flow that users know and like.

Easy to learn and use

The MET/TEMP II user interface guides you through configuring/running a calibration test, calculating sensor coefficients, and preparing a report of calibration. Calibration professionals of all levels will can easily learn and benefit from the time saving features of MET/TEMP II software.

Choice of calibration method (comparison, fixed-point, or mixed)

You may calibrate most of your secondary standard sensors against a reference sensor or against calibrated heat sources. But do you need a higher level of accuracy than a comparison calibration can give you? MET/TEMP II can calibrate your secondary standard or primary standard sensors using fixed-point cells. If you prefer, MET/TEMP II lets you combine comparison and fixed-point cell measurements during the same calibration. You can also do a triple-point of water measurement before and/or after your comparison points.

Heat source calibrations

Would you like to calibrate your heat sources also? MET/TEMP II can perform heat source calibrations for Fluke Calibration dry-wells and Micro-Baths.

Support for many test equipment configurations

Perform calibrations using a variety of digital thermometer readouts, from handhelds to high-precision bench-top models, and an assortment of heat sources including dry-wells, Metrology Wells, Micro Baths, calibration baths and furnaces.

Automatically log ambient conditions

MET/TEMP II can log ambient temperature and humidity automatically during calibration using the 1620A “DewK” Thermo-Hygrometer.

Asset management

MET/TEMP II maintains all test equipment information and calibration status in a database, as well as unit under test (UUT) sensor information including customer names and address, which are used when printing reports. MET/TEMP II can also interface with the Fluke MET/TRACK® database.

Coefficient calculation for many sensor types

The Coefficients and Tables utility calculates characterization coefficients for PRT, thermistor, and thermocouple probes. The types of coefficients that can be calculated are ITS-90, IPTS-68, Callendar-Van Dusen, and polynomial functions for PRTs; polynomial for thermistors; and coefficients for thermocouple types B, E, J, K, N, R, S, T, and AuPt. Characterization coefficients and test data acquired by MET/TEMP II can be exported to a text file.

Data quality check

Are you concerned about the quality of the data acquired from a questionable sensor? The Coefficients and Tables utility calculates residuals at each set-point to give you an indication of the quality of the data used to characterize the sensor.

Interpolation tables

After you have characterized a sensor, you can generate temperature versus resistance, temperature versus ratio or temperature versus voltage interpolation tables using the calculated characterization coefficients. Interpolation tables can be printed as part of the report of calibration, or exported to a delimited ASCII text file for importing into other analysis software.

ANSI/NCSL compliant report of calibration

MET/TEMP II produces reports of calibration compliant to ANSI/NCSL Z540.3.

Fluke Calibration instruments supported

Thermometer readouts

  • 1502A/1504 Tweener
  • 1523/1524 Reference Thermometers
  • 1529 Chub-E4 Readout
  • 1560 Black Stack (with optional modules)
  • 1594A/1595A Super Thermometer (2590 multiplexer optional)
  • 1586A Super-DAQ Precision Temperature Scanner

Temperature sources

  • 9142/9143/9144 Field Metrology Wells
  • 9190A Ultra-Cool Field Metrology Well
  • 9170/9171/9172/9173 Metrology Wells
  • 9103/9140 Dry-Well Calibrators
  • 9009 Dual-Block Calibrator
  • 9011 Dual-Well Calibrator
  • 9100S/9102S Handheld Dry-Well
  • 9101 Zero-Point Dry-Well
  • 6020/6022/6024 Hot Oil Baths
  • 6050H Extremely Hot Salt Bath
  • 6054/6055/7007 Deep Well Baths
  • 6102/7102/7103 Micro-Baths
  • 6330/7320/7340/7380 Compact Baths
  • 6331/73X1 Deep Well Compact Baths
  • 7008/7040/7037/7012/7011 Cold Baths
  • 7009/7108/7015 Resistor Baths
  • 7080 Really Cold Bath
  • 7312 Triple Point of Water Maintenance Bath
  • 9150 Thermocouple Calibration Furnace
  • 9118A Thermocouple Calibration Furnace
  • 590X/591X/592X/594X Fixed Point Cells
  • 1620A Digital Thermometer-Hygrometer
  • 9132/9133 Infrared Calibrators
  • 6109A/7109A Portable Calibration Baths

Ambient temperature monitor

  • 1620A DigitalThermometer-Hygrometer

Note: A number of discontinued Fluke Calibration instruments are also supported by MET/TEMP II. Please contact an authorized Fluke Calibration Service Center if you have a question about equipment supported by MET/TEMP II v5.1.

System requirements

Hardware

  • Computer with 1 gigahertz (GHz) or faster 32-bit (x86) or 64-bit (x64) processor
  • 1 gigabyte (GB) RAM (32-bit) or 2 GB RAM (64-bit)
  • VGA monitor or better
  • CD-ROM drive for software installation
  • Minimum 100 MB disk space for software installation
  • USB or RS-232 port

Software

One of the following Microsoft operating systems:

  • Windows 7 32-bit or 64-bit
  • Windows 8/8.1 32-bit or 64-bit
  • Windows 10 32-bit or 64-bit

MET/TEMP II V5.1 Equipment

The following required equipment is included with the MET/TEMP II V5.1 Software models (9938-16-V5, 9938-25-V5, and 9938-25-UK-V5):

  • MET/TEMP II V5.1 Software CD and license
  • SmartSwitch (allows up to 6 temperature sources to be connected and automated)
  • AC adapter
  • RS-232 data cable
  • USB to RS-232 adapter

Note: The MET/TEMP II V5.1 Software Upgrade (9938-V5-UPG) does not include the SmartSwitch, AC adapter, RS-232 data cable, and USB to RS-232 adapter. It requires use of existing MET/TEMP II equipment.

The following additional equipment may be needed (not included with MET/TEMP II V5.1 Software or Software Upgrade):

  • Up to 6 null modem cables to connect test equipment to the SmartSwitch ports. Note: RS-232 null modem cables come standard with Fluke Calibration temperature sources and thermometer readouts. They do not need to be purchased separately unless they have been lost or damaged.

用戶評(píng)論

發(fā)布評(píng)論
評(píng)價(jià)時(shí)間 類別 詳細(xì)內(nèi)容 評(píng)價(jià)者 IP地址
總共條  本頁(yè)條

留言咨詢

內(nèi)容聲明:

您訪問(wèn)的MET/TEMP II Temperature Calibration Software v5.1產(chǎn)品信息,由福祿克測(cè)試儀器(上海)有限公司自行發(fā)布提供,產(chǎn)品價(jià)格為面議,如您想了解更多關(guān)于MET/TEMP II Temperature Calibration Software v5.1型號(hào)、參數(shù)、用途等信息,歡迎咨詢。

該內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé),為保障安全,建議您在購(gòu)買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)以及產(chǎn)品質(zhì)量!

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息:

企業(yè)未開(kāi)通此功能
詳詢客服 : 0571-87759679
招远市| 屏边| 荔浦县| 神池县| 五河县| 荃湾区| 凤翔县| 安远县| 武安市| 旬邑县| 龙川县| 昔阳县| 六盘水市| 紫阳县| 宣威市| 桦南县| 敦煌市| 盐城市| 工布江达县| 女性| 那曲县| 沙洋县| 深州市| 安吉县| 定安县| 城市| 确山县| 锦州市| 聊城市| 嵩明县| 保康县| 琼海市| 皋兰县| 桓仁| 通渭县| 两当县| 康定县| 金阳县| 大足县| 江永县| 桐庐县|